- 대화정밀공업은 최고 품질의 자재를 생산하기 위해 노력합니다.
- Epoxy Resin
- Goods View
- DH-150 Super-low Viscosity DH-200 Low Viscosity DH-203 Medium Viscosity DH-207A High Viscosity DH-200W Grouting for Wet DH-002 Grouting for Elastic DH-800 Grouting for Underwater
-
Epoxy Resin
DH-207A High Viscosity
- Price
- inquiry
- Feature & Purpose
- 1.5mm Over of Dry-surface for crack area
- attached file
- attached file2
DH-207 is a high viscosity epoxy resin with superior adhesion strength and mechanical strength. It is designed to prevent defective injection or packing caused by running resin from injection into large crack. DH-207 prevents defective adhesion caused by running resin from mortar applied to outer wall or injection to tiles, crack hollowing caused as resin infiltrates into the parent body when recovering crack on cement or brick, or leakage to the other side of the penetrated crackIts slow hardening process makes the application easy and almost no shrinkage is found when fully hardened. It has the optimum level of viscosity and fluidity for grouting work by high pressure and low pressure injectors. The excellent adhesive strength of epoxy resin ensures that the hardened composition maintains a sufficient adhesive strength for the cement mortar, concrete and reinforcing bar etc. and does not produce de-lamination from the base member of the structure. After epoxy resin is injected, the fully hardened composition does not create any chemical action on the reinforcing bars or concrete structure, and offers an outstanding durability by preventing corrosion. Compared to cement mortar or concrete, it has superior mechanical strength in all respects including compressive strength, bending strength and tensile strength etc. You can choose between the for injection which is suitable for low pressure injector and high pressure injector and the for sealing which has a strong flow-prevention effect and is suitable for using a high-strength putty knife. Grouting of large cracks of all types of concrete structure without vibration. It is used for the repairing of cracks of over 1.5mm when the measured width of a crack is larger than the allowable width in case the target member is structural member, or when the structural stability, durability, waterproof should be considered regardless of the identity of the target member. Applications are as follows.
Repair and reinforcement of cracks in Pc plate, concrete molding products Grouting reinforcement of aged, weakened parts of concrete Repair and reinforcement of cracks on slab and upper plate Grouting of loosened gap of concrete plastering mortar and tile etc Reinforcement of steel plate when it is used Grouting for machinery foundation DH-207A Dimension Details DH-207A Dimension Details Classification Main Component Hardening Component Remarks Exterior Appearance White Liquid Brown Liquid - Mixing Rate 2 1 Weight Ratio Specific Gravity 1.05 ± 0.1 0.99 ± 0.1 23±0.5℃ Pot Life(Min) 60 ± 10< 23±0.5℃ Tack Free Time(Hours) 14±5 23±0.5℃ Hardening Time(Hours) 24~36 - Packing Unit 10kg 5kg - DH-207A Property Data DH-207A Property Data Test Category Result Value Base Value Test Method Compression Strength ( N/㎟ ) 86.8 Over 50 KS F 4923 Adhesive Strength ( N/㎟ ) 9.4 Over 6 Seal Breaking Expansion Rate ( % ) 9.6 Under 10 Seal Strength ( N/㎟ ) 54.2 Over 15 Hardening Contraction Rate ( % ) 0.7 Under 3 Heating Change Weight Change Rate ( % ) 1.3 Under 5 (110±3℃,168hr) Volume Change Rate ( % ) 0.1 Under 5
Pot Life the period of time during which you can work without a change in viscosity after resin and hardener are mixed. Tack Free the state of hardening in which you can lightly touch the mixed resin with your hand, but the hardened material does not stick. Hardening Time the time it takes for the mixed resin to be hardened enough to realize about 80% of final mechanical strength.
① It is specially designed to endure high pressure that is applied. Injected resin won't flow backward and this packer is also specially designed not to leak resin around stabilized and fixed packer.
② This is 1 component type high-pressure injection equipment that is specially manufactured to fill on a leakage and fracture spot by using polyurethane foam and epoxy injection material.
The following work guideline provides you with an explanation on the packer grouting method by means of a representative injection device when DH-270A High Viscosity Grouting Material is used. You are free to change the materials depending upon the site condition. Please refer to the reinjector method and syringe grouting method to learn how to use.Inspection of cracks and surface treatment Work process shall be determined by checking in advance the condition, width, depth of cracks.Remove dust or dirt from the area to be sealed with a wire brush and remove dirt from the surface by using a detergent like soap or thinner if any oily substance still remains. By using gas burner, if needed, dry the inside of cracks as much as possible before you start sealing so that you can remove moss or excessive moisture from the inside or surroundings of cracks. Sealing of cracks Sealing shall be done on cracks with epoxy sealing material, 1mm thick and 30mm wide, to prevent the injected epoxy from leaking. If sealing is not properly done on cracks, loss of epoxy resin can occur due to the damage of sealing when epoxy resin is injected. Therefore, you should pay special attention while you work. Drilling holes If the thickness of concrete is less than 10cm, you should drill cracks directly. If the thickness of concrete is between 10cm and 45cm, you should drill holes penetrating the cracks in 45 degrees at a distance of 1/5 away from cracks. If the thickness of concrete is over 50cm, you should drill holes penetrating the cracks in 45 degrees at 20cm~30cm away from the cracks. Drilled holes should zigzag along the cracks at an interval of 15cm~20cm. (average 5~6 holes should be drilled for per meter) Mixing of epoxy resin Mix DH-207A high viscosity grouting materials in mixture ratio of 2:1 according to the designated mixing formula (weight base). In the beginning, you should mix small amount because pot life varies greatly depending on the temperature of the materials and site. Injection of epoxy Inject DH-207A high viscosity grouting material by means of high pressure injection device or grease gun. The starting injection pressure shall be around 10kg/cm²~20kg/cm². Move to the next packer at the time when the hose becomes taut at the first packer. Be careful not to inject with the pressure of over 50kg/ cm². Otherwise, sealing can be damaged and epoxy resin will be lost. Removal of Packer You may remove packer after one day in summer, or two days in winter, when the epoxy resin is hardened. You can remove packer by hitting it with a hammer or bending it with vice pliers. Finishing Work Clean the sealing by grinding with a grinder. If needed, you can carry out the finishing work with flexible cracker cover material and follow-up painting. All the equipments and tools that are used for this operation should be cleaned when the operation is finished. Detergent such as M.E.K, Acetone, Xylene, Toluene and epoxy thinner should be used when cleaning. If the Foam is smeared on your skin during the performance, wash it immediately with flowing water.- When you treating medical fluid, make sure you wear protective helmet, goggle clothes and other protective devices.
- If the medical fluid is smeared on your skin, wash it off immediately and clean up with soapy water.
- All the hand tools and equipments that are used for this operation should be cleaned with thinner thoroughly.
- If you are working in sealed room, then make sure to conduct constraint ventilation for clean air.
- If the medical fluid is smeared on your skin and causes skin trouble, then you should go see specialist for prescription.
- If the temperature is below 5℃, then you must artificially raise up the temperature of medical fluid. This way you can get proper Pot Life.
- If the atmosphere temperature is high and the area is humid, Pot Life of medical fluid quickens. On the contrary, Pot Life will slow down in low temperature area.
- Be aware of it before you conduct the operation.Recommended temperature for storage is 10~25℃ with no moisture. Store it in cool area. Storing period is about 6 months in sealed condition however it can be corrupted according to storing area and conditions. Preferably use it as soon as possible.
Main Contents
-
Daehwa Precision
-
Mechanical injection packer
-
concrete crack injection repair
-
concrete repair kits
-
Single component Injection Pump
-
Twin Line Injection Pump
-
Acrylic Injection Pump
-
Grouting Injection Pump
-
grouting injection
-
polyurethane injection system
-
resin injection pump
-
repair of concrete
-
epoxy injections
-
epoxy injection system
-
epoxy injection systems
-
concrete repair epoxy injection
-
Water stop grouting Method
-
Reinjector Injection Method
-
Syringe Injection Method
-
concrete repair epoxy mortar